Anton Paar Poland sp. z o.o.
- ul. Osmańska 14, Warszawa, 02-823 Warszawa, Poland
- www.anton-paar.com/pl-pl
Description
Products
Drive output: 4.2 kW (MS4), 8 kW (MS8), 16 kW (MS16)
Torque and speed:
MS4: 200 Nm, 0.2–185 min⁻¹
MS8: 400 Nm, 0.2–200 min⁻¹
MS16: 400 Nm, 0.2–400 min⁻¹ / 500 Nm, 0.2–275 min⁻¹
Speed deviation: 0.2% (digital feedback)
Temperature control:
MS4: 6 zones (integrated in drive unit)
MS8: 8 zones (in drive unit – 8E or in docking stations)
MS16: 8 zones (in docking stations)
Connectivity: MetaBridge Connect, WebAPI, Labfolder (LIMS)
Safety: emergency motor stop, non-contact magnetic safety switch on the cover
Power supply:
MS4: 3×400 V 50/60 Hz + N + PE, 32 A (optional 3×220 V without transformer)
MS8/MS16: 3×400 V 50/60 Hz + N + PE, 63 A (optional ~3×220–230 V)
Dimensions (W × H × D):
MS4: 700 × 870 × 950 mm
MS8/MS16: 600 × 1500 × 1370 mm
Weight: 154 kg (MS4), 311 kg (MS8/MS16)
Sample size: From 0.1 g up to max. 130 cm³
Resolution: 0.01 mg / 1 ppm / 0.0001% H₂O
Precision: Better than ±1.4% of full-scale value
Measurement range:
0.0001% to 60% H₂O (relative)
0.01% to 60 mg H₂O (absolute)
Measurement temperature: 60 °C to 200 °C (1 °C increments)
Measurement time: approx. 10–60 min, depending on sample
Display units: %, ppm, mg
Minimum temperature: −35 °C (ACM), −90 °C (RCM), −170 °C (NCM)
Maximum temperature: 700 °C (ACM), 600 °C (RCM/NCM)
Heating rate: up to 300 K/min
Cooling rate: up to 150 K/min (ACM), 200 K/min (RCM/NCM)
Cooling performance:
10 K/min to: 5 °C (ACM), −55 °C (RCM), −150 °C (NCM)
5 K/min to: −15 °C (ACM), −70 °C (RCM), −160 °C (NCM)
Temperature accuracy (In): <0.1 K
Enthalpy accuracy (In): <1%
Measurement range: ±2500 mW
Compatibility:
Julia DSC 300: ACM
Julia DSC 500: ACM, RCM, NCM
FTIR spectrometers with DLaTGS detector and hermetically sealed optics (gold-coated mirrors, KBr). Spectral range 350–7,500 cm⁻¹, S/N 55,000:1, accuracy <0.05 cm⁻¹, repeatability <0.0005 cm⁻¹. Measurement time <30 s. IR source: SiC, VCSEL laser (Class 1), cube corner interferometer.
Resolution:
LYZA 3000: 1.4–16 cm⁻¹
LYZA 7000: 1.0–16 cm⁻¹
Operating temperature: 10–30 °C. Cell compartment: 152 mm.
Dimensions: 365 × 315 × 204 mm (3000) / 382 mm height (7000).
Weight: 11.7 kg / 12.8 kg.
Power: 100–240 V. Consumption: 24 W (3000), 30 W / 15 W eco (7000).
Interfaces: USB, CAN, Ethernet.
Wi-Fi and .png export only in LYZA 7000.
Operation:
3000: AP Spectroscopy Suite
7000: 10.1” touchscreen, 32 GB storage
Data: .csv, .pdf, .spc (7000 also .png), AP Connect.
Libraries: factory and user-defined.
Compliance: 21 CFR Part 11.
Screw diameter:
12 mm (A 12/36), 20 mm (A 20/40, S 20/40), 30 mm (S 30/40)
L/D: 36 (A 12/36), 40 (others)
Max. speed:
A 12/36: 1200 rpm
A 20/40: up to 200 rpm (MetaStation 8/8E, up to 800 rpm with gearbox); up to 400 rpm (MetaStation 16, up to 1200 rpm with gearbox)
S 20/40, S 30/40: 1200 rpm
Max. screw torque:
2 × 15 Nm (A 12/36), 2 × 40 Nm (A 20/40, S 20/40), 2 × 150 Nm (S 30/40)
Max. power:
n/a (A), 9.5 kW (S 20/40), 39 kW (S 30/40)
Connectivity:
A 12/36: compatible with all MetaStation drive units
A 20/40: compatible with MetaStation 8/8E and 16
S: standalone units
Power supply:
A: via drive unit
S 20/40: 3×400 V (63 A) / 3×230 V (76 A)
S 30/40: 3×400 V (118 A)
Dimensions (W × H × D):
A 12/36: 1240 × 600 × 1300 mm (with stand) / 450 mm depth without stand
A 20/40: 2000 × 500 × 1565 mm
S 20/40: 2013 × 450 × 1566 mm
S 30/40: 2310 × 500 × 1590 mm
Weight:
175 kg (A 12/36), 420 kg (A 20/40), 480 kg (S 20/40), 850 kg (S 30/40)